PX2000 SERIES [ POWER AMPLIFIERS WITH AFS ]

________________________________________________________________________________________

VARIANTS :
PX2100 | 120W 100V
PX2200 | 240W 100V
PX2300 | 360W 100V
PX2400 | 480W 100V
PX2200

INTRODUCTION

PX series of power amplifiers are equipped with AFS (Auto Fault Sensor) which generate pilot tones internally and automatically diagnose and detect any faulty condition that may occur at the output end. Pilot tones are generated at intervals to avoid straining the power packs, and this shall prolong the life span of the units.

 

FEATURES

TICK Incorporating Auto Fault Sensing (AFS) circuitry for self monitoring of its output
TICK Pilot tone switchable for normal operation without AFS
TICK Interval PT generation to avoid continuous loading of the amplifier
TICK Thermal protection by muting input signal (typically 85º at heat sink)
TICK Temperature dependent dual speed cooling fan
TICK Manual reset circuit breaker for AC mains and DC input
TICK Balanced input signal with gain control and selectable grounding option
TICK AC and DC operation for uniterrupted operation during power failure

 

TECHNICAL SPECIFICATIONS

  PX2100 PX2200 PX2300 PX2400
Power requirement
230 / 240V ac (24V DC backup)
24V DC requirement
8A
19A
23A
29A
Power consumption (load) ac
1.4A
3A
3.4A
4.5A
Power consumption (s/by)
0.4A
Input sensitivity
1V / 10 K Ohm
Input gain control
-15 dB to 0 dB
Input connection
XLR balanced line input
Rated output (rms)
120W 100V line
240W 100V line 360W 100V line 480W 100V line
Output voltage ( 4 Ohm ) V rms
22
31
38
44
Output impedance ( 70 V line )
42
21
13
10.2
                              ( 100V line )
83
42
27.8
20.8
Frequency response
180 - 17 KHz (+/- 3dB at 1 KHz) with low cut
S/N ratio
> 60 dB @ 1 KHz
Protections
Thermal, momentary output short circuit,
AC and DC circuit breaker, input signal clip
Indicators
AC mains, Clip, Protect, Input level
Pilot tone, Fault
Cooling system
Dual speed fan with heat sensing
 
FAULT DETECTIONS
Detection intervals
10 seconds
Detection response
15 - 25 seconds
Detection method
Internal Pilot Tone generated at 20 KHz
Failure recovery time
20 seconds max
Failure output
Dry contact ( NO at 3A rating )
 
Dimensions (WxHxD)
PX2100 : 482 x 88 x 300 mm
 
PX2200 / 2300 / 2400 : 482 x 133 x 300 mm
Weight
10.8 kg
19.8 kg
20.9 kg
24.8 kg

 

CLICK Rear View Of PX2200 / 2300 / 2400 CLICK Rear View Of PX2100

 

Friday, May 31, 2013 12:55 PM