PX2000 SERIES [ POWER AMPLIFIERS WITH AFS ]
________________________________________________________________________________________
| VARIANTS : |
| PX2100 | 120W 100V |
| PX2200 | 240W 100V |
| PX2300 | 360W 100V |
| PX2400 | 480W 100V |
INTRODUCTION
PX series of power amplifiers are equipped with AFS (Auto Fault Sensor) which generate pilot tones internally and automatically diagnose and detect any faulty condition that may occur at the output end. Pilot tones are generated at intervals to avoid straining the power packs, and this shall prolong the life span of the units.
FEATURES
 |
Incorporating Auto Fault Sensing (AFS) circuitry for self monitoring of its output |
 |
Pilot tone switchable for normal operation without AFS |
 |
Interval PT generation to avoid continuous loading of the amplifier |
 |
Thermal protection by muting input signal (typically 85º at heat sink) |
 |
Temperature dependent dual speed cooling fan |
 |
Manual reset circuit breaker for AC mains and DC input |
 |
Balanced input signal with gain control and selectable grounding option |
 |
AC and DC operation for uniterrupted operation during power failure |
TECHNICAL SPECIFICATIONS
| |
PX2100 |
PX2200 |
PX2300 |
PX2400 |
Power requirement |
230 / 240V ac (24V DC backup) |
24V DC requirement |
8A |
19A |
23A |
29A |
Power consumption (load) ac |
1.4A |
3A |
3.4A |
4.5A |
Power consumption (s/by) |
0.4A |
Input sensitivity |
1V / 10 K Ohm |
Input gain control |
-15 dB to 0 dB |
Input connection |
XLR balanced line input |
Rated output (rms) |
120W 100V line
|
240W 100V line |
360W 100V line |
480W 100V line |
Output voltage ( 4 Ohm ) V rms |
22 |
31 |
38 |
44 |
Output impedance ( 70 V line ) |
42 |
21 |
13 |
10.2 |
( 100V line ) |
83 |
42 |
27.8 |
20.8 |
Frequency response |
180 - 17 KHz (+/- 3dB at 1 KHz) with low cut |
S/N ratio |
> 60 dB @ 1 KHz |
Protections
|
Thermal, momentary output short circuit, |
AC and DC circuit breaker, input signal clip |
Indicators |
AC mains, Clip, Protect, Input level |
Pilot tone, Fault |
Cooling system |
Dual speed fan with heat sensing |
| |
FAULT DETECTIONS |
Detection intervals |
10 seconds |
Detection response |
15 - 25 seconds |
Detection method |
Internal Pilot Tone generated at 20 KHz |
Failure recovery time |
20 seconds max |
Failure output |
Dry contact ( NO at 3A rating ) |
| |
Dimensions (WxHxD) |
PX2100 : 482 x 88 x 300 mm |
| |
PX2200 / 2300 / 2400 : 482 x 133 x 300 mm |
Weight |
10.8 kg |
19.8 kg |
20.9 kg |
24.8 kg |
Rear View Of PX2200 / 2300 / 2400 Rear View Of PX2100
|