| VARIANTS : |
| QP2125 | 125W 100V LINE |
| QP2250 | 250W 100V LINE |
| QP2375 | 375W 100V LINE |
| QP2500 | 500W 100V LINE |
INTRODUCTION
Introducing the new generation of amplifiers from Amperes... QP2000 SERIES. Features offered surpassed the needs of most installation, as they are carefully designed by listening to the feedbacks from installers throughout the years and built according to the stringent requirements of users.
Available in various rating from 125W to 500W 100V line in compact 2 hu height, the new circuitry has been further enhanced, incorporating digital settings for tone preferences and other control features, higher efficiency, better frequency response and extra protection features. Each unit is addressable with RS485 output port. With monitoring software, the conditions and setting of the installed amplifiers can be conveniently monitored. Anothe distinguished feature is its built if AFS with FAult Changeover mechanism, thereby providing simpler interconnections for Automated Fault Changeover setup, and definitely lower BOQ.
QP series would definitely enhance your setup, providing years of reliable service and with Amperes' star rated service, you can be assured of getting the only right product in the market.
FEATURES
 |
Available in 125 / 250 / 375 / 500W 100V line output in compact 2 hu height |
 |
Digital setting for various control features such as bass, treble, fan speed, etc |
 |
Built in Auto Fault Sensor and Changeover relay for standby fault changeover |
 |
RS485 data port for remote monitoring3 |
 |
Fan speed option ensures longer lifespan of the unit |
 |
Overload, thermal cut off, short circuit and fuse protections |
 |
High efficiency for lower power consumption and lesser back up battery capacity |
 |
2 hu height for lesser rack space |
TECHNICAL SPECIFICATIONS
| |
QP2125 |
QP2250 |
QP2375 |
QP2500 |
Power requirement |
230 / 240V ac or 24V DC back up supply |
Power Consumption (240V DC) |
220VA (1.2A) |
440VA (1.8A) |
580VA (2.4A) |
720VA (3A) |
Current Consumption @ 24V DC |
8A |
15A |
20A |
25A |
Standby current @ 24V DC |
0.2 |
0.25 |
0.3A |
0.32 |
Input signal |
1V / 10 K Ohm; balanced via XLR female |
Input gain controls |
-40 to 0 dB |
Rated output (100V, RMS) |
125W |
250W |
375W |
500W |
4 Ohm output voltage |
22.3V |
31.6V |
38.7V |
44.8V |
Output impedance (max load) |
80 Ohm
|
40 Ohm |
27 Ohm |
20 Ohm |
Frequency response |
70Hz - 15 Khz @ 1 KHz +/-3 dB |
S/N ratio |
>70 dB @ 1 KHz, 1V |
THD + N |
<0.18% |
Protections |
Thermal, Short circuit, Overload, Fuse |
Cut off temperature |
75 Deg C |
Cooling system |
Auto temperature controlled fan speed with auto on |
Indications |
LCD with temp, audio level and address |
Communication |
RS485, 19.2 kbps |
Fault sensing |
Internal Pilot Tone,Detection at i5 to 25 secs at 10 secs intervals |
Fault detection response |
Standby amplifier relay activation, fault dry contact |
Dimensions (W x H x D) |
482 x 88 x 335 mm |
Net weight (kg) |
12 |
13 |
16 |
18 |
Gross weight |
13.2 |
14.2 |
17.2 |
19.2 |
|