top of page

AX3800 MK II

8 Duty 1 Standby Automatic Amplifier Changeover

AX3800 MK II is an advanced amplifier changeover unit that supports 8 duty and 1 standby (8+1) with dual I/O auto switching, cascading, priority switching, pilot tone injection and RS485 remote monitoring. Suitable for large-scale installations.

Dual input and output automatic switching

Built-in 20kHz pilot tone to reduce phantom amplifier workload

RS485 port for remote monitoring and dry contact for integration

Fault detection and recovery within 7 to 15 seconds

Introduction

AX3800 MK II is an advanced amplifier changeover unit with automatic input and 100V output switching to ensure continuous operation during amplifier failure. It offers fast fault detection, stable performance, and reduced noise. With cascading support, one standby amplifier can back up multiple duty units (up to 16), making it suitable for large-scale installations. It features priority single-takeover to prevent overload and a built-in 20kHz pilot tone for efficient operation. RS485 remote monitoring and a built-in buzzer alarm provide reliable fault indication, making it ideal for matrix and large-scale PA systems.


Note: AX3800 MK II is an upgraded version of the now discontinued AX3800 with all other features retained. 

Packing information

  • Carton size: 555 (L) x 295 (W) x 165 (H) mm

  • Gross weight: 4.50 kg

  • 1 unit per carton

  • Introduction

    AX3800 MK II is an advanced amplifier changeover unit with automatic input and 100V output switching to ensure continuous operation during amplifier failure. It offers fast fault detection, stable performance, and reduced noise. With cascading support, one standby amplifier can back up multiple duty units (up to 16), making it suitable for large-scale installations. It features priority single-takeover to prevent overload and a built-in 20kHz pilot tone for efficient operation. RS485 remote monitoring and a built-in buzzer alarm provide reliable fault indication, making it ideal for matrix and large-scale PA systems.


    Note: AX3800 MK II is an upgraded version of the now discontinued AX3800 with all other features retained. 

    Packing information

    • Carton size: 555 (L) x 295 (W) x 165 (H) mm

    • Gross weight: 4.50 kg

    • 1 unit per carton


  • AX3800 MK II

    Power Requirements


    Operating voltage

    24V DC, 1A

    Power consumption

    2.5W (0.11A)

    Standby consumption

    2.3W (0.95A)

    Input signal

    8 Ch balanced line signal

    Input impedance

    10k Ohm

    Audio output gain

    Unity

    Pilot tone interval

    8 seconds / channel

    Pilot tone frequency

    20 kHz (±5%)

    Detection line

    70 / 100V line

    Detection level

    5V rms min

    Failure detection time

    20 seconds (max)

    Failure recovery time

    20 seconds (max)

    Zone load rating

    1000W at 100V line input

    Status indication LED

    Normal / Fault / Changeover

    Changeover alert

    Buzzer alarm with ON/OFF switch

    Changeover section

    Input and output simultaneously

    Physical Specifications


    Dimensions (W x H x D)

    482 x 88 x 180 mm

    Net weight

    3.55 kg

    Note: The specification parameters may be changed, added, or omitted without prior notice. Last updated on 17 Apr 2026.

    • 8 duty amplifiers and 1 standby unit (8+1), cascading up to 16 duty units

    • 1000W per channel rating

    • Dual input and output (I/O) changeover with auto switching

    • Priority switching to prevent overload with single unit takeover

    • Built-in 20kHz pilot tone to reduce phantom amplifier workload

    • RS485 port for remote monitoring and dry contact for system integration

    • Fault detection and recovery within 7 to 15 seconds

    • Input link switch for easy source connections

    • Channel isolation switch for unused channels

    • LED indicators for status, faults, and changeovers

    • Built-in buzzer alarm for fault detection with ON/OFF control

  • Catalogue

    File Type: PDF

    Version: Year 24/25

    Instruction Manual

    File Type: PDF

    Version: -

    AutoCAD

    File Type: DWG

    Version: Year 24/25

    CE Marking

    File Type: PDF

    Version: -

Contact us today

Interested in this product? Contact us for more information.

Registered association members of

FMM_logo.jpg
matrade_logo.png
TEEAM_logo.png

International recognitions

ISO 9001_UKAS_URS_PDF-1.png
ce_logo.png

© 1999 - 2026 Amperes Electronics Sdn Bhd. All Rights Reserved.

Payment

paypal_icon.gif

© 1999 - 2024 Amperes Electronics Sdn Bhd. All Rights Reserved.

PayPal payment is only applicable for payment from outside of Malaysia

Sales Office (Malaysia)

70, Jalan Industri PBP 3,

Taman Perindustrian Pusat Bandar Puchong,

47100 Puchong, Selangor, Malaysia.

Tel: +603-5882 7757 / 7758

Production Factory (Malaysia)

2, Jalan Meranti Puchong D25@Meranti Puchong

47120 Puchong, Selangor, Malaysia

Export Sales Office (Singapore)

Amperes Asia Pte Ltd

(Co Reg: 201102253E)

1, North Bridge Road, #13-03, High Street Centre, Singapore 179094

amperes_logo_profile_fit_w.png

Amperes Electronics Sdn Bhd

SSM Registration No: 200001006420 (509025-X)

Your Trusted PA System Manufacturer since 1999

  • Amperes Electronics Facebook
  • Amperes Electronics LinkedIn
  • Amperes Electronics YouTube
  • Amperes Electronics Instagram
bottom of page