LS4808

8 Ch Speaker Line Surveillance

LS4808 is an 8-channel speaker line monitor that detects faults using impedance measurement, with easy setup and remote testing support.

Available in 8 (LS4808) or 16 channels (LS4816)

Reduce PA disruption with short test signals

Detection time adjustable from 1 min to 48 hrs

Bi-colour LEDs for fault indication

Introduction

LS4808 and LS4816 are next-generation speaker line monitoring units, designed to replace the long-standing LS4600. Available in 8-channel (LS4808) and 16-channel (LS4816) versions, these units offer fast, accurate monitoring of speaker circuit integrity including ground leakage, short circuits, and open circuits, using advanced impedance measurement—eliminating the need for end-of-line resistors or blocking capacitors.


Powered by a high-performance processor and refined measurement algorithms, LS4808 and LS4816 deliver faster detection with greater precision. Dual detection modes—Basic and Advanced which allow flexibility to suit installation needs, while a trigger monitoring function allows enables timed activations when linked to a timer. Fully compliant with EN54 requirements, these units are ideal for ensuring reliable speaker line monitoring in safety-critical PA and EVAC systems.

Packing information

  • Carton size: 555 (L) x 295 (W) x 95 (H) mm

  • Gross weight: 2.75 kg

  • 1 unit(s) per carton

  • Introduction

    LS4808 and LS4816 are next-generation speaker line monitoring units, designed to replace the long-standing LS4600. Available in 8-channel (LS4808) and 16-channel (LS4816) versions, these units offer fast, accurate monitoring of speaker circuit integrity including ground leakage, short circuits, and open circuits, using advanced impedance measurement—eliminating the need for end-of-line resistors or blocking capacitors.


    Powered by a high-performance processor and refined measurement algorithms, LS4808 and LS4816 deliver faster detection with greater precision. Dual detection modes—Basic and Advanced which allow flexibility to suit installation needs, while a trigger monitoring function allows enables timed activations when linked to a timer. Fully compliant with EN54 requirements, these units are ideal for ensuring reliable speaker line monitoring in safety-critical PA and EVAC systems.

    Packing information

    • Carton size: 555 (L) x 295 (W) x 95 (H) mm

    • Gross weight: 2.75 kg

    • 1 unit(s) per carton


  • LS4808

    Power requirements


    Operating voltage

    24V DC via PS9400

    Power consumption

    3.8W

    Measurement, pilot tone, & setting


    Capacity

    8

    Impedance detection range

    10 to 10k Ohm

    Power measurement range

    10 to 1000W 100V line

    Measurement accuracy

    +/- 5% within range

    Pilot tone injection frequency

    1 kHz

    Pilot tone signal output level

    5V sine

    Monitor triggering

    Auto / remote trigger

    Transmitted detection period

    0.5 seconds per channel (max)

    Detection interval

    User preset from 1 min to 48 hours

    Sensitivity setting

    User preset at each channel

    Indicators + LED

    Normal ; Fault ; Buzzer ; Auto run

    Display LCD

    2 x 16 characters with back light

    Audible output signal

    Continuous buzzer with OFF option

    Dry contact setting

    3A

    DC output in detection mode

    24V DC for individual channel

    Data interface

    RS485 : 19.2 kbps

    Case


    Dimensions (W x H x D)

    482 x 44 x 180 mm

    Weight

    2.15kg

    Note: The specification parameters may be changed, added, or omitted without prior notice.

    • Available in 8-channel (LS4808) or 16-channel (LS4816) models

    • Uses impedance measurement, allowing speaker circuit branching

    • End-of-line resistors are not required

    • Offers both basic and advanced detection modes for flexibility and accuracy

    • Uses short test signals to minimize disruption to PA operation

    • Supports automatic or manual fault detection with external test triggers

    • Adjustable detection intervals from 1 minute to 48 hours

    • Optional isolation of faulty circuits for safety and reliability

    • Bi-color LED indicators to show circuit fault status

    • AUX 24V DC output to override volume controls during testing

    • RS485 port allows remote testing via PMX III and iPX5500 interface

  • Catalogue

    File Type: PDF

    Version: Year 24/25

    Instruction Manual

    File Type: PDF

    Version: -

    AutoCAD

    File Type: DWG

    Version: Year 24/25

    CE Marking

    File Type: PDF

    Version: -

Contact us today

Interested in this product? Contact us for more information.

Registered association members of

FMM_logo.jpg
matrade_logo.png
TEEAM_logo.png

International recognitions

ISO 9001_UKAS_URS_PDF-1.png
ce_logo.png

© 1999 - 2024 Amperes Electronics Sdn Bhd. All Rights Reserved.

Payment

paypal_icon.gif

PayPal payment is only applicable for payment from outside of Malaysia

© 1999 - 2024 Amperes Electronics Sdn Bhd. All Rights Reserved.

Sales Office (Malaysia)

70, Jalan Industri PBP 3,

Taman Perindustrian Pusat Bandar Puchong 47100, Puchong, Selangor, Malaysia.

Tel: +603-5882 7757 / 7758

Production Factory (Malaysia)

2, Jalan Meranti Puchong D25@Meranti Puchong 47120 Puchong, Selangor, Malaysia

Amperes Asia Pte Ltd

Export Sales Office - Singapore

(Co Reg: 201102253E)

1, North Bridge Road, #13-03, High Street Centre, Singapore 179094

Subscribe to our newsletter

amperes_logo_profile_fit_w.png

(Co Reg: 509025 X)

Precision Design, Absolute Confidence

  • Amperes Electronics Facebook
  • Amperes Electronics LinkedIn
  • Amperes Electronics YouTube
  • Amperes Electronics Instagram
bottom of page