top of page

LS4808

8 Ch Speaker Line Surveillance

LS4808 is an 8-channel speaker line monitor that detects faults using impedance measurement, with easy setup and remote testing support.

Available in 8 (LS4808) or 16 channels (LS4816)

Reduce PA disruption with short test signals

Detection time adjustable from 1 min to 48 hrs

Bi-colour LEDs for fault indication

Introduction

LS4808 and LS4816 are next-generation speaker line monitoring units, designed to replace the long-standing LS4600. Available in 8-channel (LS4808) and 16-channel (LS4816) versions, these units offer fast, accurate monitoring of speaker circuit integrity including ground leakage, short circuits, and open circuits, using advanced impedance measurement—eliminating the need for end-of-line resistors or blocking capacitors.


Powered by a high-performance processor and refined measurement algorithms, LS4808 and LS4816 deliver faster detection with greater precision. Dual detection modes—Basic and Advanced which allow flexibility to suit installation needs, while a trigger monitoring function allows enables timed activations when linked to a timer. Fully compliant with EN54 requirements, these units are ideal for ensuring reliable speaker line monitoring in safety-critical PA and EVAC systems.

Packing information

  • Carton size: 555 (L) x 295 (W) x 95 (H) mm

  • Gross weight: 2.75 kg

  • 1 unit(s) per carton

  • Introduction

    LS4808 and LS4816 are next-generation speaker line monitoring units, designed to replace the long-standing LS4600. Available in 8-channel (LS4808) and 16-channel (LS4816) versions, these units offer fast, accurate monitoring of speaker circuit integrity including ground leakage, short circuits, and open circuits, using advanced impedance measurement—eliminating the need for end-of-line resistors or blocking capacitors.


    Powered by a high-performance processor and refined measurement algorithms, LS4808 and LS4816 deliver faster detection with greater precision. Dual detection modes—Basic and Advanced which allow flexibility to suit installation needs, while a trigger monitoring function allows enables timed activations when linked to a timer. Fully compliant with EN54 requirements, these units are ideal for ensuring reliable speaker line monitoring in safety-critical PA and EVAC systems.

    Packing information

    • Carton size: 555 (L) x 295 (W) x 95 (H) mm

    • Gross weight: 2.75 kg

    • 1 unit(s) per carton


  • LS4808

    Power requirements


    Operating voltage

    24V DC via PS9400

    Power consumption

    3.8W

    Measurement, pilot tone, & setting


    Capacity

    8

    Impedance detection range

    10 to 10k Ohm

    Power measurement range

    10 to 1000W 100V line

    Measurement accuracy

    +/- 5% within range

    Pilot tone injection frequency

    1 kHz

    Pilot tone signal output level

    5V sine

    Monitor triggering

    Auto / remote trigger

    Transmitted detection period

    0.5 seconds per channel (max)

    Detection interval

    User preset from 1 min to 48 hours

    Sensitivity setting

    User preset at each channel

    Indicators + LED

    Normal ; Fault ; Buzzer ; Auto run

    Display LCD

    2 x 16 characters with back light

    Audible output signal

    Continuous buzzer with OFF option

    Dry contact setting

    3A

    DC output in detection mode

    24V DC for individual channel

    Data interface

    RS485 : 19.2 kbps

    Case


    Dimensions (W x H x D)

    482 x 44 x 180 mm

    Weight

    2.15kg

    Note: The specification parameters may be changed, added, or omitted without prior notice.

    • Available in 8-channel (LS4808) or 16-channel (LS4816) models

    • Uses impedance measurement, allowing speaker circuit branching

    • End-of-line resistors are not required

    • Offers both basic and advanced detection modes for flexibility and accuracy

    • Uses short test signals to minimize disruption to PA operation

    • Supports automatic or manual fault detection with external test triggers

    • Adjustable detection intervals from 1 minute to 48 hours

    • Optional isolation of faulty circuits for safety and reliability

    • Bi-color LED indicators to show circuit fault status

    • AUX 24V DC output to override volume controls during testing

    • RS485 port allows remote testing via PMX III and iPX5500 interface

  • Catalogue

    File Type: PDF

    Version: Year 24/25

    Instruction Manual

    File Type: PDF

    Version: -

    AutoCAD

    File Type: DWG

    Version: Year 24/25

    CE Marking

    File Type: PDF

    Version: -

Contact us today

Interested in this product? Contact us for more information.

Registered association members of

FMM_logo.jpg
matrade_logo.png
TEEAM_logo.png

International recognitions

ISO 9001_UKAS_URS_PDF-1.png
ce_logo.png
© 1999 - 2025 Amperes Electronics Sdn Bhd. All Rights Reserved.

Payment

paypal_icon.gif

© 1999 - 2024 Amperes Electronics Sdn Bhd. All Rights Reserved.

PayPal payment is only applicable for payment from outside of Malaysia

Sales Office (Malaysia)

70, Jalan Industri PBP 3,

Taman Perindustrian Pusat Bandar Puchong,

47100 Puchong, Selangor, Malaysia.

Tel: +603-5882 7757 / 7758

Production Factory (Malaysia)

2, Jalan Meranti Puchong D25@Meranti Puchong

47120 Puchong, Selangor, Malaysia

Export Sales Office (Singapore)

Amperes Asia Pte Ltd

(Co Reg: 201102253E)

1, North Bridge Road, #13-03, High Street Centre, Singapore 179094

amperes_logo_profile_fit_w.png

Amperes Electronics Sdn Bhd

Registration No: 200001006420 (509025-X)

Your Trusted PA System Manufacturer since 1999

  • Amperes Electronics Facebook
  • Amperes Electronics LinkedIn
  • Amperes Electronics YouTube
  • Amperes Electronics Instagram
bottom of page