top of page

QP2000 Series

Class AB Power Amplifier with AFS

QP2000 Series is a durable range of Class AB amplifiers with auto fault sensor (AFS) and standby changeover relay for long-term public address installations. Available in various power ratings of 125W (QP2125), 250W (QP2250), 375W (QP2375), 500W (QP2500).

Built-in protections against inrush current, overload etc

RS485 port for remote controls and monitoring

Digital controls for volume, bass, treble, and fan speed

Operates on both AC and DC power during power outages

Introduction

QP2000 Series is a reliable range of Class AB power amplifiers available in four models — 125W (QP2125), 250W (QP2250), 375W (QP2375), and 500W (QP2500) — designed for long-term performance in public address installations. Built with Auto Fault Sensor (AFS) and an integrated standby changeover relay, the series enables automatic detection and switching to a backup unit during amplifier failure, ensuring continuous operation. Each unit includes an RS485 port for remote monitoring and control via PC (through UART converter) or IP network using iPX5500 interface. Trusted for over a decade in countless projects, the QP2000 Series offers durability, intelligent protection, and flexibility for centralized or distributed PA systems.


Series model variants:

  • QP2125: 125W 100V Line

  • QP2250: 250W 100V Line

  • QP2375: 375W 100V Line

  • QP2500: 500W 100V Line

Packing information

  • Carton size : 550 (L) x 465 (W) x 180 (H) mm

  • Gross weight : QP2125: 13.5 kg / QP2250: 14.6 kg / QP2375: 18 kg / QP2500: 19.9 kg

  • 1 unit(s) per carton

  • Introduction

    QP2000 Series is a reliable range of Class AB power amplifiers available in four models — 125W (QP2125), 250W (QP2250), 375W (QP2375), and 500W (QP2500) — designed for long-term performance in public address installations. Built with Auto Fault Sensor (AFS) and an integrated standby changeover relay, the series enables automatic detection and switching to a backup unit during amplifier failure, ensuring continuous operation. Each unit includes an RS485 port for remote monitoring and control via PC (through UART converter) or IP network using iPX5500 interface. Trusted for over a decade in countless projects, the QP2000 Series offers durability, intelligent protection, and flexibility for centralized or distributed PA systems.


    Series model variants:

    • QP2125: 125W 100V Line

    • QP2250: 250W 100V Line

    • QP2375: 375W 100V Line

    • QP2500: 500W 100V Line

    Packing information

    • Carton size : 550 (L) x 465 (W) x 180 (H) mm

    • Gross weight : QP2125: 13.5 kg / QP2250: 14.6 kg / QP2375: 18 kg / QP2500: 19.9 kg

    • 1 unit(s) per carton


  • QP2000 Series


    QP2125

    QP2250

    QP2375

    QP2500

    Power requirements





    Power rating

    125W 100V line

    250W 100V line

    375W 100V line

    500W 100V line

    Operating voltage

    220 - 240V AC or 24V DC back up supply

    220 - 240V AC or 24V DC back up supply

    220 - 240V AC or 24V DC back up supply

    220 - 240V AC or 24V DC back up supply

    Power consumption

    294 VA (1.1A)

    447 VA (1.7A)

    749 VA (2.9A)

    873 VA (3.3A)

    Current consumption

    5.9A

    10.6A

    16.7A

    19.6A

    Standby current

    0.7A

    0.7A

    0.7A

    0.9A

    Input, output and controls





    Input signal (sensitivity)

    1V (+4 dBU) / 10k Ohm via Phoenix connectors

    1V (+4 dBU) / 10k Ohm via Phoenix connectors

    1V (+4 dBU) / 10k Ohm via Phoenix connectors

    1V (+4 dBU) / 10k Ohm via Phoenix connectors

    Input gain controls

    -40 to 40 dBU

    -40 to 40 dBU

    -40 to 40 dBU

    -40 to 40 dBU

    Output

    70 / 100V line and 4 Ohm

    70 / 100V line and 4 Ohm

    70 / 100V line and 4 Ohm

    70 / 100V line and 4 Ohm

    4 Ohm output voltage

    22.3V

    31.6V

    38.7V

    44.8V

    Output impedance (max load)

    80 Ohm

    40 Ohm

    27 Ohm

    20 Ohm

    Frequency response

    120 - 15 kHz @ 1 kHz +/- 3 dB

    120 - 15 kHz @ 1 kHz +/- 3 dB

    120 - 15 kHz @ 1 kHz +/- 3 dB

    120 - 15 kHz @ 1 kHz +/- 3 dB

    S/N ratio

    >70 dB @ 1 kHz, 1V

    >70 dB @ 1 kHz, 1V

    >70 dB @ 1 kHz, 1V

    >70 dB @ 1 kHz, 1V

    THD + N

    <1%

    <1%

    <1%

    <1%

    Protections

    Thermal, short circuit, overload, fuse, in-rush current

    Thermal, short circuit, overload, fuse, in-rush current

    Thermal, short circuit, overload, fuse, in-rush current

    Thermal, short circuit, overload, fuse, in-rush current

    Cut off temperature

    75°C

    75°C

    75°C

    75°C

    Cooling system

    Auto temperature controlled cooling fan with auto ON

    Auto temperature controlled cooling fan with auto ON

    Auto temperature controlled cooling fan with auto ON

    Auto temperature controlled cooling fan with auto ON

    Indicators

    LCD with temperature, audio level and address

    LCD with temperature, audio level and address

    LCD with temperature, audio level and address

    LCD with temperature, audio level and address

    Communication

    RS485 ; 19.2 kbps

    RS485 ; 19.2 kbps

    RS485 ; 19.2 kbps

    RS485 ; 19.2 kbps

    Fault sensing

    Internal Pilot Ton : 20 kHz, detection at 15 - 20 secs, 10 secs interval

    Internal Pilot Ton : 20 kHz, detection at 15 - 20 secs, 10 secs interval

    Internal Pilot Ton : 20 kHz, detection at 15 - 20 secs, 10 secs interval

    Internal Pilot Ton : 20 kHz, detection at 15 - 20 secs, 10 secs interval

    Fault detection response

    Standby amplifier relay activation, fault dry contact

    Standby amplifier relay activation, fault dry contact

    Standby amplifier relay activation, fault dry contact

    Standby amplifier relay activation, fault dry contact

    Case





    Dimensions (W x H x D)

    482 x 88 x 335 mm

    482 x 88 x 335 mm

    482 x 88 x 335 mm

    482 x 88 x 335 mm

    Weight

    11.60 kg

    12.70 kg

    16.50 kg

    18.05 kg

    Note: The specification parameters may be changed, added, or omitted without prior notice.

    • Available in 125W, 250W, 375W, and 500W 100V output in compact 2U size

    • Built-in auto fault sensor (AFS) and backup relay for automatic switching

    • Digital controls for volume, bass, treble, and fan speed

    • Adjustable fan modes for better cooling

    • Supports RS485 and UART ports for remote monitoring and control

    • Equipped with multiple protections, including inrush current, overload, thermal, short circuit, and fuse

    • Operates on both AC and DC power for continuous use during outages

    • Energy-efficient design to reduce power consumption

  • Catalogue

    File Type: PDF

    Version: Year 24/25

    Instruction Manual

    File Type: PDF

    Version: -

    AutoCAD

    File Type: DWG

    Version: -

    CE Marking

    File Type: PDF

    Version: -

Contact us today

Interested in this product? Contact us for more information.

Registered association members of

FMM_logo.jpg
matrade_logo.png
TEEAM_logo.png

International recognitions

ISO 9001_UKAS_URS_PDF-1.png
ce_logo.png

© 1999 - 2024 Amperes Electronics Sdn Bhd. All Rights Reserved.

Payment

paypal_icon.gif

PayPal payment is only applicable for payment from outside of Malaysia

© 1999 - 2024 Amperes Electronics Sdn Bhd. All Rights Reserved.

Sales Office (Malaysia)

70, Jalan Industri PBP 3,

Taman Perindustrian Pusat Bandar Puchong 47100, Puchong, Selangor, Malaysia.

Tel: +603-5882 7757 / 7758

Production Factory (Malaysia)

2, Jalan Meranti Puchong D25@Meranti Puchong 47120 Puchong, Selangor, Malaysia

Amperes Asia Pte Ltd

Export Sales Office - Singapore

(Co Reg: 201102253E)

1, North Bridge Road, #13-03, High Street Centre, Singapore 179094

Subscribe to our newsletter

amperes_logo_profile_fit_w.png

(Co Reg: 509025 X)

Precision Design, Absolute Confidence

  • Amperes Electronics Facebook
  • Amperes Electronics LinkedIn
  • Amperes Electronics YouTube
  • Amperes Electronics Instagram
bottom of page